Short answer
Weibull analysis fits a curve to failure times. The shape parameter β tells you how the failure rate changes: below 1 is early failure, near 1 is random failure, and above 1 is wear-out. The characteristic life η is the time by which about two thirds of units have failed. Units that still work must count as suspensions.
The two parameters
F(t) = 1 − exp(−(t / η)^β)
- β (shape): below about 0.95 means infant mortality. Above about 1.05 means wear-out.
- η (characteristic life): the time at which about two thirds of units have failed.
Units that still run
Most plants have many more units that work than units that failed. If you drop the units that work, the fit gives a life that is too short. A unit that works is a suspension: it did not fail yet, and its run time counts.
How many failures you need
- Fewer than 2 failures: no fit is possible.
- Fewer than 6 failures: the fit is a small sample. Read it as a hint, not as a result.
- A confidence bound shows how much the answer can change. A wide bound means too little data.
A B-life, for example B10, is the time by which one unit in ten has failed. It is a common input for a replacement interval.
Questions and answers
What is the difference between MTBF and Weibull?
MTBF is one average number. A Weibull fit also shows if the failure rate rises or falls with age, and this is what you need to choose a maintenance strategy.
Does Reliatic count the units that still run?
Yes. The time since the last failure counts as a suspension, and maximum likelihood is the default when there is one.
Terms in the glossary
More guides
- What is risk-based inspection (RBI)?
- API 580 vs API 581: what is the difference?
- How to calculate remaining life from thickness readings
- What is a condition monitoring location (CML)?
- What is t-min (minimum required thickness)?
- Short-term vs long-term corrosion rate
- RPN vs criticality: which one ranks your assets?
- RBI software compared: established suites and Reliatic